中文摘要

本專案目的在改善手術器械之潔淨度,以確保滅菌品質落實感染控制。當器械未確實清潔時不僅影響器械的使用壽命,也會造成滅菌不完全而引起手術部位的感染,專案前發現手術器械未洗淨件數每月平均為94 件 (0.54 %),經現況分析發現導因有未預處理隔夜器械、廠借器械結構複雜且未規劃定期教育訓練、缺乏相關設備、省略標準作業流程及查核制度不夠完善等因素,予運用決策矩陣分析方法,擬定解決辦法為每月定期舉辦教育訓練課程、採購相關設備、增加人力、修訂標準作業流程及查核機制等,使專案實施後,2015 年1 月~ 4 月手術器械未洗淨之件數每月平均降至17 件 (0.09 %),改善了手術器械之潔淨度,確保滅菌品質。

英文摘要

The purpose of this project was to improve the hygiene of surgical instruments to ensure sterilization quality and infection control. A lack of surgical instrument hygiene not only influences the service life of the instruments but also affects sterilization quality and can cause surgical-site infections. The average quantity of unclean surgical instruments measured before this project was 94 (0.54%) per month. After analysis, we determined this to be a result of instruments not being cleaned overnight, complicated procedures for loaning instruments, a lack of relevant equipment, insufficient training for nurses, failure to adhere to procedures, and inadequate checking guidelines. We adopted Decision Matrix Analysis as a method of evaluation and propose the following solutions: (1) monthly training programs for nurses, (2) purchasing relevant equipment, and (3) increasing the standards of operating procedures and checking guidelines. The average number of unclean surgical instruments decreased from 94 to 17 (0.09%) per month between January and April 2015. Hygiene of surgical instruments improved and quality of sterilization was ensured.

主题分类 醫藥衛生 > 預防保健與衛生學
醫藥衛生 > 社會醫學
参考文献
  1. 衛福部疾病管制局(2013 年,7 月).滅菌監測之感染控制措施指引.取自http://www.cdc.gov.tw/professional/info.aspx?treeid=beac9c103df952c4&nowtreeid=29e258298351d73e&tid=FC2D18631F460778
  2. Association for the Advancement of Medical Instrumentation(2010).Comprehensive Guide to Steam Sterilization and Sterility Assurance in Health Care Facilities.
  3. Association of periOperative Registered Nurses(2013).AORN Standards, recommended practices, and guidelines.Denver:AORN.
  4. Azizi, J.,Anderson, S. G.,Murphy, S.,Pryce, S.(2012).Uphill grime: Process improvement in surgical instrument cleaning.Association of periOperation Registered Nurses Journal,96(2),152-162.
  5. Hansen, D.,Hilgenhoner, M.,Popp, W.(2008).ATP bioluminescence for kitchen hygiene and cleaning control of surgical instruments.International Journal of Infection Control,4(1),1-4.
  6. Marion, K.,Freney, J.,James, G.,Bergeron, E.,Renaud, F. N. R.,Costerton, J. W.(2006).Using an efficient biofilm detaching agent: Anessential step for the improvement of endoscope reprocessing protocols.Journal of Hospital Infection,64(2),136-142.
  7. Spry, C.(2008).The importance of cleaning in earnest.OR Manager,24(5),21-24.
  8. 王寶清、陳珍梅(2011)。醫療器械清洗方法效果探討。中國護理管理,11(5),69-70。
  9. 陳培琴、郭惜珍、黃旭華(2010)。手術器械清洗方法的對比研究。中華醫院感染學雜誌,20(18),2806-2807。
  10. 劉君、王子平、車英(2007)。兩種清洗醫療器械方法的比較研究。中國實用戶理雜誌,23(2),42。
被引用次数
  1. 楊雅如,林麗華(2020).手術器械清潔再處理流程之改善專案.嘉基護理,20(1),13-23.