英文摘要
|
A smart bed care system can effectively reduce the incidence of falls before patients leave the bed by notifying nurses in advance, who can help. This project aimed to improve nurse use of the smart bed care system. After investigation, from January 1 to January 10, 2021, the rate of nurse implementation of the smart bed care system was 45.0%. The main reasons for this were a lack of health education data, the system not being able to deal with abnormalities, the setup process being inconvenient, and nurses often forgetting to plug the mattress transmission line back into the bedside alarm after removal. Through the provision of instructions for the operation of the smart bed care system, establishment of a messaging (LINE) group to provide real-time troubleshooting, upgrading of the smart bed care system to connect with the inpatient system, and monitoring and reminding of nurses, the rate of nurse implementation of the smart bed care system was increased to 85.6%. The efficiency of smart bed care systems can only be improved through the combined use of information technology and nursing care processes. This project provides future nurses with a reference for the application of smart bed care systems, enabling them to use this technology to provide more effective care to more patients.
|
参考文献
|
-
林小玲,謝雅宜,溫明寰(2016)。使用離床報知機偵測離床降低住院病人跌倒之研究。榮總護理,33(2),164-175。
連結:
-
Cuttler, S. J.,Barr-Walker, J.,Cuttler, L.(2017).Reducing medical-surgical inpatient falls and injuries with videos, icons and alarms.BMJ Open Quality,6(2),e000119.
-
Hubbartt, B.,Davis, S. G.,Kautz, D. D.(2011).Fall prediction and prevention systems: Recent trends, challenges, and future research directions.Sensors, Rehabilitation Nursing,36(5),196-199.
-
Mileski, M.,Brooks, M.,Topinka, J. B.,Hamilton, G.,Land, C.,Mitchell, T.,Mosley, B.,McClay, R.(2019).Alarming and/or alerting device effectiveness in reducing falls in long-term care (LTC) facilities? A systematic review.Healthcare (Basel),7(1),51.
-
Potter, P.,Allen, K.,Costantinou, E.,Klinkenberg, W. D.,Malen, J.,Norris, T.,O'Connor, E.,Roney, W.,& Tymkew, H. H.(2016).Anatomy of inpatient falls: Examining fall events captured by depth sensor technology.The Joint Commission Journal on Quality and Patient Safety,42(5),225-231.
-
Potter, P.,Allen, K.,Costantinou, E.,Klinkenberg, W. D.,Malen, J.,Norris, T.,O'Connor, E.,Roney, W.,Tymkew H. H.,Wolf, L.(2017).Evaluation of sensor technology to detect fall risk and prevent falls in acute care.The Joint Commission Journal on Quality and Patient Safety,43(8),414-421.
-
Seow, J. P.,Chua, T. L.,Aloweni, F.,Lim, S. H.,Ang, S. Y.(2022).Effectiveness of an integrated three-mode bed exit alarm system in reducing inpatient falls within an acute care setting.Japan Journal of Nursing Science,19(1),1-7.
-
Subermaniam, K.,Welfred, R.,Subramanian, P.,Chinna, K.,Ibrahim, F.,Mohktar, M. S.,Tan, M. P.(2017).The effectiveness of a wireless modular bed absence sensor device for fall prevention among older inpatients.Front Public Health,4,292.
-
Vandenberg, A. E.,van Beijnum, B. J.,Overdevest, V. G.,Capezuti, E.,Johnson, T. M., II(2017).US and Dutch nurse experiences with fall prevention technology within nursing home environment and workflow: A qualitative study.Geriatric Nursing,38(4),276-282.
-
林湘玉,林小玲,溫明寰(2017)。提升胃腸科病房離床報知機使用遵從率專案。高雄護理雜誌,34(2),45-51。
|