题名

鋼筋混凝土十字形樁帽之抗剪強度:以四樁承載之樁帽為例

并列篇名

SHEAR STRENGTHS OF REINFORCED CONCRETE CROSS-SHAPED PILE CAPS: TAKING THE PILE CAPS WITH FOUR PILES AS AN EXAMPLE

作者

呂文堯(Wen-Yao Lu);黃裕盛(Yu-Sheng Huang);蔡瑞庭(Jui-Ting Tsai);柯學成(Hsueh-Cheng Ko)

关键词

鋼筋混凝土 ; 十字形樁帽 ; 抗剪強度 ; 壓-拉桿 ; reinforced concrete ; cross-shaped pile caps ; shear strengths ; strut-and tie

期刊名称

技術學刊

卷期/出版年月

37卷4期(2022 / 12 / 01)

页次

251 - 263

内容语文

繁體中文

中文摘要

本研究共製作9座鋼筋混凝土十字形樁帽進行試驗,探討混凝土強度、樁心間距及撓曲鋼筋參數等對十字形樁帽剪力傳遞行為之影響。本研究並以軟化壓-拉桿(Softened strut-and-tie, SST)模型及ACI規範之壓-拉桿(Strut-and-tie, ST)模型做為分析工具,來預測9座鋼筋混凝土十字形樁帽之抗剪強度。研究結果顯示,抗壓強度81.3 MPa之高強度混凝土樁帽其抗剪強度約為抗壓強度28.0 MPa之普通強度混凝土樁帽抗剪強度之1.5倍。樁帽之抗剪強度隨著剪跨-深比之增加而降低。樁帽之抗剪強度會隨著撓曲鋼筋參數之增加而增加。SST模型及ACI規範之ST模型皆能精確預測鋼筋混凝土樁帽之抗剪強度。ST模型無法預測十字形樁帽之破壞模式。

英文摘要

In this study, a total of 9 reinforced concrete cross-shaped pile caps were produced for experiments to investigate the effect of concrete strength, pile centroid spacing and flexural steel bar parameters on the shear transferred behavior of the cross-shaped pile cap. In this study, the softened strut-and-tie (SST) model and the strut-and-tie (ST) model of the ACI Code were used as analysis tools to predict shear strength of 9 reinforced concrete cross-shaped pile caps. Research results show that the shear strength of the high-strength concrete pile caps with a compressive strength of 81.3 MPa is about 1.5 times that of the normal-strength concrete pile caps with a compressive strength of 28.0 MPa. The shear strength of the pile caps decreases as the shear span-to-depth ratio increases. The shear strength of the pile cap will increase with the increase of the flexural reinforcement parameters. Both the SST model and the ST model of the ACI Code can predict the shear strength of reinforced concrete cross-shaped pile caps well. The ST model cannot predict the failure mode of the cross-shaped pile cap.

主题分类 工程學 > 工程學綜合
参考文献
  1. Lu, W. Y.,Lin, I. J.,Hwang, S. J.(2009).Shear Strength of Reinforced Concrete Corbels.Magazine of Concrete Research,61(10),807-813.
    連結:
  2. ACI=American Concrete Institute(2019).ACI (American Concrete Institute). 2019. Building code requirements for structural concrete (ACI 318-19) and Commentary (ACI 318R-19). Farmington Hills, MI: American Concrete Institute..
  3. Adebar, P.,Chou, L.(1996).Design of Deep Pile Caps by Strut-and-Tie Models.ACI Structural Journal,93(4),437-448.
  4. Adebar, P.,Kuchma, D.,Collins, M. P.(1990).Strut-and-Tie Models for the Design of Pile Caps: An Experimental Study.ACI Structural Journal,87(1),81-92.
  5. Clarke, J. L.(1973).,London, UK:Cement and Concrete Association.
  6. Gogate, A. B.,Sabnis, G. M.(1980).Design of Thick Pile Caps.ACI Journal,77(1),18-22.
  7. Hwang, S. J.,Lee, H. J.(2002).Strength Prediction for Discontinuity Regions by Softened Strut-and-Tie Model.Journal of Structural Engineering,128(12),1519-1526.
  8. Hwang, S. J.,Lu, W. Y.,Lee, H. J.(2000).Shear Strength Prediction for Reinforced Concrete Corbels.ACI Structural Journal,97(4),543-552.
  9. Hwang, S. J.,Lu, W. Y.,Lee, H. J.(2000).Shear Strength Prediction for Deep Beams.ACI Structural Journal,97(3),367-376.
  10. Lu, W. Y.,Lee, T. M.,Ko, H. C.,Tsai, J. T.(2021).Ultimate Loads for Reinforced Concrete Square Pile Caps.Magazine of Concrete Research,74(12),633-647.
  11. Lu, W. Y.,Lin, I. J.,Yu, H. W.(2013).Shear Strength of Reinforced Concrete Deep Beams.ACI Structural Journal,110(4),671-680.
  12. Lu, W. Y.,Lin, I. J.,Yu, H. W.(2012).Behaviour of Reinforced Concrete Dapped-End Beams.Magazine of Concrete Research,64(9),793-805.
  13. Meléndez, C.,Sagaseta, J.,Sosa, P. F. M.,Rubio, L. P.(2019).Refined Three-Dimensional Strut-and-Tie Model for Analysis and Design of Four-Pile Caps.ACI Structural Journal,116(4),15-29.
  14. Mogili, S.,Hwang, S. J.(2021).Softened Strut-and-Tie Model for Shear and Flexural Strengths of Reinforced Concrete Pile Caps.Journal of structural Engineering,147(11),04021169.
  15. Otsuki, K.,Suzuki, K.(1996).Experimental Study on Bending Ultimate Strength of Four Pile Caps.Journal of Structural and Construction Engineering (Transactions of AIJ),61(482),93-102.
  16. Park, J.,Kuchma, D.,de Souza, R. A.(2008).Strength Predictions of Pile Caps by a Strut-and-Tie Model Approach.Canadian Journal of Civil Engineering,35(12),1399-1413.
  17. Sabnis, G. M.,Gogate, A. B.(1984).Investigation of Thick Slab (Pile Cap) Behavior.ACI Journal,81(1),35-39.
  18. Suzuki, K.,Otsuki, K.(2001).Experimental Study on Corner Shear Failure of Pile Caps.Transactions of the Japan Concrete Institute,23,303-310.
  19. Suzuki, K.,Otsuki, K.,Tsubata, T.(2001).Influence of Edge Distance on Failure Mechanism of Pile Caps.Transactions of the Japan Concrete Institute,22,361-368.
  20. Suzuki, K.,Otsuki, K.,Tsubata, T.(2000).Experimental Study on Four-Pile Caps with Taper.Transactions of the Japan Concrete Institute,21,327-334.
  21. Suzuki, K.,Otsuki, K.,Tsubata, T.(1999).Influence of Bar Arrangement on Ultimate Strength of Four-Pile Caps.Transactions of the Japan Concrete Institute,20,195-202.