中文摘要

抽水井設計為臺中都會區卵礫石層深開挖工程的重要課題,而卵礫石層的透水係數為設計之關鍵參數。本研究於某一大型深開挖工程基地,規劃試坑開挖、鑽探取樣、現地抽水試驗、鑽孔內透水試驗與卵礫石基質透水試驗,探討不同試驗方法所求參數之差異,並探討其在抽水系統設計之適用性。研究結果顯示定流量與變流量抽水試驗所得透水係數K_r相近,其範圍約為2.0 × 10^(-2) ~ 3.6 ×10^(-2)(cm/s),以此設計之抽水控制方案,於後續施工已證實其合理性。主抽水井單井分析之參數與多井分析結果差異不大。鑽孔內透水試驗之參數遠較抽水試驗為小,不適用於抽水井設計。基質透水試驗之參數較抽水試驗小,但差異小於一個量級,經過經驗修正後,可應用於小規模深開挖工程。最後總結各種透水試驗應用在卵礫石地層之優缺點與適用性,供工程界參考應用。

英文摘要

The design of the pumping well is an important subject of the deep excavation project constructed in the gravelly boulder deposit in Taichung metropolitan area, and the permeability coefficient of the deposit is the key parameter of the design. This study planned pit excavation, drilling and sampling, in-situ pumping test, borehole slug test and laboratory permeability test on the matrix of gravelly boulder deposit in a large-scale deep excavation site to explore the discrepancies of the coefficient of permeability derived by different test methods, and to explore their applicability in pumping system design. The research results show that the coefficients of permeability K_r obtained from the constant flow and variable flow pumping tests are similar, and their range is about 2.0 × 10^(-2) ~ 3.6 × 10^(-2) (cm/s). The pumping control scheme designed in this coefficient has been confirmed as rationale in the subsequent construction. The parameters from the single-well analysis of the main pumping well are close to the results of the multi-well analysis. The parameters of the borehole slug test are much smaller than those of the pumping tests, and are not suitable for the design of pumping wells. The parameters of the matrix permeability test are smaller than those of the pumping tests, but the difference is less than one order of magnitude. After modification by experience, it can be applied to small-scale deep excavation projects. Finally, the advantages, disadvantages and applicability of various permeability tests in the gravelly boulder deposit are summarized for reference and application in the engineering community.

主题分类 工程學 > 土木與建築工程
工程學 > 水利工程
工程學 > 市政與環境工程
参考文献
  1. Agarwal, R. G.(1980).A new method to account for producing time effects when drawdown type curves are used to analyze pressure buildup and other test data.Proceedings of the 55th Annual Fall Technical Conference and Exhibition of the Society of Petroleum Engineers
  2. Boulton, N. S.(1954).Unsteady radial flow to a pumped well allowing for delayed yield from storage.International Association of Scientific Hydrology,37,472-477.
  3. Butler, J. J.,McElwee, C.D.(1990).Variable-rate pumping tests for radially symmetric non-uniform aquifers.Water Resources Research,26(2),291-306.
  4. Cooper, H. H. and Jacob C. E., “A generalized graphical method for evaluating formation constants and summarizing well field history,” Transaction of the American Geophysical Union, Vol. 27, pp. 526-534 (1946).
  5. Duffield, G. M.(2007).AQTESOLV for Windows User’s Guide.Reston:HydroSOLVE, Inc..
  6. Hvorslev, M. J.(1951).Corps of Engrs sburg, MississippCorps of Engrs sburg, Mississipp,Vicksburg, Mississippi:Waterways Exper. Sta. Corps of Engrs, U.S. Army.
  7. Li, N.,Wen, Z. Z.,Zhu, Q.(2018).The single-well test dilemma: the skin effect and variable-rate pumping perspective.Hydrogeology Journal,26,2521-2529.
  8. Moench, A. F.,Garabedian, S. P.,LeBlanc, D. R.(2001).Massachusetts, U.S. Geological Survey Professional PaperMassachusetts, U.S. Geological Survey Professional Paper,Reston, USA:.
  9. Moench, A.F.(1997).Flow to a well of finite diameter in a homogeneous, anisotropic water-table aquifer.Water Resources Research,33(6),1397-1407.
  10. Neuman, S. P.(1972).Theory of flow in unconfined aquifers considering delayed response of the water table.Water Resources Research,8(4),1031-1044.
  11. Neuman, S. P.(1974).Effects of partial penetration on flow in unconfined aquifers considering delayed aquifer response.Water Resources Research,10(2),303-312.
  12. Neuman, S. P.(1975).Analysis of pumping test data from anisotropic unconfined aquifers considering delayed gravity response.Water Resources Research,11(2),329-342.
  13. Theis, C. V., “The relation between the lowering of the piezometric surface and the rate and discharge of a well using ground water storage,” Transaction of the American Geophysical Union 16th Annual Meeting (1935).
  14. Walker, D. D.,Roberts, R. M.(2003).Flow dimensions corresponding to hydrogeologic conditions.Water Resources Research,39(12),1349.
  15. 內政部營建署,建築物基礎構造設計規範 (2011)。
  16. 社團法人日本地盤工學會,單孔透水試驗方法,地盤工學會基準,JGS 1314-2003 (2003)。
  17. 高世鍊(2014)。現地抽水試驗漫談-規劃、執行、分析及配井設計。大地技師期刊,8,24-37。
  18. 高世鍊,郭晉榮,洪菁(2013)。變水量抽水試驗之操作與分析方法案例。第十五屆大地工程學術研討會論文集,雲林:
  19. 張吉佐,陳逸駿,嚴世傑,蔡宜璋(1996)。台灣地區中北部卵礫石層工程性質及施工探討。地工技術,55,35-46。
  20. 許世孟,顧承宇,鍾明劍(2008)。岩盤工址之水力特性調查與案例應用。地工技術,115,39-48。
  21. 曾豊升,何樹根,譚國豪,陳定遠,廖肇邦,李昆芳(2022)。臺中卵礫石層全套管樁之施工性及地下水影響探討案例。地工技術,171,107-118。
  22. 經濟部中央地質調查所(2000).臺灣地質圖─臺中圖幅,圖幅第 24 號.
  23. 經濟部中央地質調查所,地下水補注地質敏感區劃定計畫書-臺中盆地,G0005 (2015)。
  24. 經濟部水利署,經濟部水利署施工規範 (2022)。
  25. 經濟部水資源統一規劃委員會(1975)。,未出版
  26. 褚炳麟,潘進明,張國雄(1996)。台灣西部卵礫石層現地之大地工程性質。地工技術,55,47-58。
  27. 鄧屬予(1996)。台灣卵礫石層的地質背景。地工技術,55,5-24。
  28. 璞真建設股份有限公司與勤美股份有限公司(2019).勤美之森(台中市西區綠園道)現地抽水試驗及分析報告書.臺北: