题名

台灣地區托兒所室內空氣品質及其決定因素

并列篇名

Indoor Air Quality and Its Determinants in Taiwan Child Care Centers

DOI

10.6377/JA.201103.0005

作者

楊武泰(Wu-Tai Yang);江哲銘(Che-Ming Chiang);何明錦(Ming-Chin Ho);陳瑞鈴(Jui-Lin Chen);羅時麒(Shih-Chi Lo)

关键词

托兒所 ; 室內空氣污染物 ; 決定因素 ; 通風條件 ; Child Care Centers CCCs ; Indoor Pollutants ; Determinants ; Ventilaion Conditions

期刊名称

建築學報

卷期/出版年月

75期(2011 / 03 / 28)

页次

61 - 80

内容语文

繁體中文

中文摘要

本研究旨在調查台灣地區托兒所室內空氣污染物濃度並推斷其決定因素。除了在不同通風條件下進行空氣品質現場量測,並收集室內空氣品質相關環境變數,再依序透過單變量統計分析及多元回歸分析從10項環境變數中篩選出室內空氣品質決定因素。比較不同通風條件之室內空氣品質後發現,相較於使用空調條件,自然通風條件之室內CO及PM10濃度較高,決定因素爲室外濃度、區位屬性及廚房毗鄰程度。相較於自然通風條件,使用空調條件之室內CO2及HCHO濃度較高,決定因素爲室外濃度、窗簾裝設、換氣率、地板清潔頻率及人員密度。日後托兒所孩童流行病學研究,應將上述決定因素視爲暴露危害分級之代表性指標。

英文摘要

This study aims to investigate indoor pollutants concentrations in Taiwan child care centers (CCCs) and evaluates their determinants. Measurements were performed in different ventilation conditions while information on CCCs characteristics was collected. Determinants of indoor pollutant levels were evaluated with univariate analyses and regression analyses. The results showed indoor CO and PM10 concentration levels were higher in naturally ventilated (NV) than air-conditioned (AC) CCCs and determinants of indoor pollutant levels in NV CCCs were outdoor concentration, location and proximity to kitchens. Besides, indoor CD2 and HCHO concentration levels were higher in AC than NV CCCs and determinants of indoor pollutant levels in AC CCCs were outdoor concentration, presence of curtains, air exchange rates, floor cleaning and occupant density. Future epidemiological analyses in CCCa should consider these determinants in classifying exposures as surrogate indicators of sources.

主题分类 工程學 > 土木與建築工程
参考文献
  1. 江哲銘、楊武泰、李俊璋、何明錦、陳瑞鈴、羅時麒(2009)。建築室內空氣品質最佳化量測方法之研究─以辦公建築及寺廟建築為例。建築學報,第70期增刊(技術專刊)=No.70(Special Issue on Technology),93-110。
    連結:
  2. World Health Organization (2005) Indoor air pollution and health, http://www.who.int/mediacentre/factsheets/fs292/en/index.html
  3. Smith, K.E. (2002) Who's Minding the Kids? Chile Care Arrangements: Spring 1997, http://www.census.gov/prod/2002pubs/p70-86.pdf.
  4. Chew, F. T.,Teo, J.,Quak, S. H.,Lee, B. W.(1999).Factors associated with increased respiratory symptoms among asthmatic children in Singapore.Asian Pacific Journal of Allergy and Immunology,17(3),14-153.
  5. Daisey, J. M.,Angell, W. J.,Apte, M. G.(2003).Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information.Indoor Air,13(1),53-64.
  6. Daneault, S.,Beausoleil, M.,Messing, K.(1992).Air quality during the winter in Québec day-care centers.American Journal of Public Health,82(3),432-434.
  7. Edwards, R. D.,Jurvelin, J.,Koistinen, K.,Saarela, K.,Jantunen, M.(2001).VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, Finland.Atmospheric environment,35(28),4829-4841.
  8. Ekmekcioglu, D.,Keskin, S. S.(2007).Characterization of indoor air particulate matter in selected elementary schools in Istanbul, Turkey.Indoor and Built Environment,16(2),169-176.
  9. Endo, Y.,Miyazaki, T.,Hikita, Y.,Azuma, M.,Ikeda, H.,Fukunaga, K.,Endo, G.(2001).Sampling methods and residential factors affecting formaldehyde concentration in indoor air.The Tohoku journal of experimental medicine,195(4),227-236.
  10. Etzel, R. A.(2007).Indoor and outdoor air pollution: Tobacco smoke, moulds and diseases in infants and children.International Journal of Hygiene and Environmental Health,210(5),611-616.
  11. Figley, D. A.(1985).Relation between indoor air formaldehyde concentrations and. ventilation rates for a group of sixteen new houses.Proceedings of the 78th Annual Meeting of the Air Pollution Control Association,Detroit, USA:
  12. Gu, D. S.,Shao, M.,Lu, S. H.(2008).Source apportionment of formaldehyde in urban atmosphere using primary and secondary tracers.Acta Scientiarum Naturalium Universitatis Pekinensis,44(2),317-322.
  13. Guo, H.,Lee, S. C.,Chan, L. Y.(2004).Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong.Science of the Total Environment,323(1-3),87-98.
  14. Hedge, A.,Sterling, T. D.,Sterling, E. M.,Collett, C. W.,Sterling, D. A.,Nie, V.(1989).Indoor air quality and health in two office buildings with different ventilation systems.Environment International,15(1-6),115-128.
  15. Hodgson, A. T.,Faulkner, D.,Sullivan, D. P.,DiBartolomeo, D. L.,Russell, M. L.,Fisk, W. J.(2003).Effect of outside air ventilation rate on volatile organic compound concentrations in a call center.Atmospheric Environment,37(39-40),5517-5527.
  16. Jaakkola, J. J. K.(2000).Indoor Air Quality Handbook.New York, USA:McGraw-Hill.
  17. Jones, N. C.,Thornton, C. A.,Mark, D.,Harrison, R. M.(2000).Indoor/outdoor relationships of particulate matter in domestic homes with roadside, urban and rural locations.Atmospheric Environment,34(16),2603-2612.
  18. Kagi, N.,Fujii, S.,Horiba, Y.,Namiki, N.,Ohtani, Y.,Emi, H.,Tamura, H.,Kim, Y. S.(2007).Indoor air quality for chemical and ultrafine particle contaminants from printers.Building and Environment,42(5),1949-1954.
  19. Kelly, T. J.,Smith, D. L.,Satola, J.(1999).Emission rates of formaldehyde from materials and consumer products found in California homes.Environmental Science and Technology,33(1),81-88.
  20. Kukadia, V.,Palmer, J.(1998).The effect of external atmospheric pollution on indoor air quality: A pilot study.Energy and Buildings,27(3),223-230.
  21. Lee, S. C.,Chan, L. Y.,Chiu, M. Y.(1999).Indoor and outdoor air quality investigation at 14 public places in Hong Kong.Environment International,25(4),443-450.
  22. Lee, S. C.,Chang, M.(2000).Indoor and outdoor air quality investigation at schools in Hong Kong.Chemosphere,41(1-2),109-113.
  23. Li, W. M.,Lee, S. C.,Chan, L. Y.(2001).Indoor air quality at nine shopping malls in Hong Kong.Science of the Total Environment,273(1-3),27-40.
  24. Lundqvist, G. R.,Iversen, M.,Korsgaard, J.(1982).Indoor climate in low-ventilation day care institutions.Environment International,8(1-6),139-142.
  25. Monn, Ch.,Fuchs, A.,Högger, D.,Junker, M.,Kogelschatz, D.,Roth, N.,Wanner, H.-U.(1997).Particulate matter less than 10 μm(PM10) and fine particles less than 2.5 μm(PM2.5): relationships between indoor, outdoor and personal concentrations.Science of the Total Environment,208(1-2),15-21.
  26. Ní Riain, C. M.,Mark, D.,Davies, M.,Harrison, R. M.,Byrnee, M. A.(2003).Averaging periods for indoor-outdoor ratios of pollution in naturally ventilated non-domestic buildings near a busy road.Atmospheric Environment,37(29),4121-4132.
  27. Olsen, J. H.,Dossing, M.(1982).Formaldehyde induced symptoms in day care centers.American Industrial Hygiene Association Journal,43(5),366-370.
  28. Pejtersen, J.,Clausen, G.,Sorensen, D.,Quistgaard, D.,Iwashita, G.,Zhang, Y.,Fanger, P. O.(1991).Air pollution sources in kindergartens.Proceedings of Healthy Buildings 1991,Atlanta, USA:
  29. Ruotsalainen, R.,Jaakkola, N.,Jaakkola, J. J. K.(1993).Ventilation and indoor air quality in finnish daycare centers.Environment International,19(2),109-119.
  30. Sisovic, A.,Fugas, M.(1985).Indoor concentrations of carbon monoxide in selected urban microenvironments.Environmental Monitoring and Assessment,5(2),199-204.
  31. Skaret, E.,Nordvik, V.(1998).,Oslo, Norway:Norwegian Building Research Institute.
  32. Smedje, G.,Norbäck, D.,Edling, C.(1997).Subjective indoor air quality in schools in relation to exposure.Indoor Air,7(2),143-150.
  33. Sverdrup, C.,Andersson, K.,Andersson, S.(1990).A comparative study of indoor climate and human health in 74 day care centers in Malmo, Sweden.Proceedings of Indoor Air 1990,Toronto, Canada:
  34. Teknisk Hygienisk Forum(1987).Indoor climate in kindergartens, investigation of 50 kindergartens in five norwegian counties.Trondheim, Norway:Teknisk Hygienisk Forum.
  35. Thatcher, T. L.,Layton, D. W.(1995).Deposition, resuspension, and penetration of particles within a residence.Atmospheric Environment,29(13),1487-1497.
  36. Tsuang, H. C.,Su, H. J.,Kao, F. F.,Shih, H. C.(2003).Effects of changing risk factors on increasing asthma prevalence in southern Taiwan.Paediatr Perinat Epidemiol,17(1),3-9.
  37. Willers, S.,Andersson, S.,Andersson, R.,Grantén, J.,Sverdrup, C.,Rosell, L.(1996).Sick building syndrome symptoms among the staff in schools and kindergartens: are the levels of volatile organic compounds and carbon dioxide responsible.Indoor and Built Environment,5(4),232-235.
  38. Woolf, A.(2000).Indoor Air Pollutants Affecting Child Health.Marietta, USA:Air Quality Sciences.
  39. Yu, J. H.,Lue, K. H.,Lu, K. H.,Sun, H. L.,Lin, Y. H.,Chou, M. C.(2005).The relationship of air pollution to the prevalence of allergic diseases in Taichung and Chu-Shan in 2002.Journal of Microbiology, Immunology and Infection,38(2),123-126.
  40. Zuraimi, M. S.,Tham, K. W.(2008).Indoor air quality and its determinants in tropical child care centers.Atmospheric Environment,42(9),2225-2239.
  41. 宋鴻樟(2006)。空氣污染物對國小學童氣喘之健康風險評估─總計畫暨子計畫四:不同交通流量對國小學童氣喘與鼻病毒暴露及氧化傷害健康風險評估。台北市=Taipei ROC (Taiwan):行政院國家科學委員會=National Science Council。
  42. 周伯丞(2000)。Tainan, ROC(Taiwan),國立成功大學建築研究所=National Cheng Kung University。
  43. 楊武泰、江哲銘、李俊璋、何明錦、陳瑞鈴、羅時麒(2009)。室內空氣品質之決定因子─以台灣地區托兒所為例。中華民國建築學會第二十一屆第二次建築研究成果發表會,台南市=Tainan, ROC(Taiwan):