题名 |
中國人正常網膜電圖 |
并列篇名 |
Normal ERG in Chinese |
DOI |
10.30048/ACTASOS.198805.0165 |
作者 |
張松柏(Sung-Po Chang);黃志明(Jsie-Ming Huang) |
关键词 |
electroretinogram ERG ; a-and b-wave ; ganzfeld stimulator |
期刊名称 |
台灣眼科醫學會會刊 |
卷期/出版年月 |
27卷2期(1988 / 05 / 01) |
页次 |
942 - 947 |
内容语文 |
繁體中文 |
中文摘要 |
本文報告以Cadwell Quantum 84測量80隻正常眼睛之網膜電圖(flash electroretinogram),經過30分鐘暗適應所得暗適應網膜電圖(Scotopic ERG):a波(a-wave)其latency平均為11.44 msec,振幅(amplitude)平均為174.10 μV;b波(b-wave) latency平均為30.13 msec,振幅平均為356.87 μV。 |
英文摘要 |
The ERG was recorded in 80 normal eyes. Cadwell Quantum 84 was used, and the results were recorded after dark, adaptation for 30 minutes. The average latency of a-wave is 11.44 msec, and the average amplitude of a-wave is 174.10 μV. The average latency of b-wave is 30.13 msec, and the average amplitude of b-wave is 356.87 μV. |
主题分类 |
醫藥衛生 >
外科 |