题名 |
PACER測驗和最大攝氧量相關之研究 |
并列篇名 |
Relationship between PACER test and maximal oxygen uptake |
DOI |
10.6222/pej.0033.200209.2404 |
作者 |
余鑑紘(Chien-Hung Yu);方進隆(Chin-Lung Fang) |
关键词 |
最大攝氧量 ; 800/1600公尺跑走 ; PACER ; Maximal osygen uptake, ; 800/1600m walk/run test |
期刊名称 |
體育學報 |
卷期/出版年月 |
33期(2002 / 09 / 01) |
页次 |
33 - 42 |
内容语文 |
繁體中文 |
中文摘要 |
The purpose of this study was to compare the PACER’s validity with 800/1600m walk/run test. Then we purpose to validate the test-retest reliability of PACER. Thirty-four subjects completed this study (20male, mean age: 14.35±0.88yrs, BMI: 20.10±3.14) and (14 male, mean age: 13.57±1.16yrs, BMI : 20.36±2.76). Each subjects randomized to performed the PACER, 800/1600m walk/run test and maximal exercise test through counter-balance design. Pearson’s productmoment correlation was used to compare the concurrent validity of PACER test to 800/1600m walk/run test ,and attempted to develop an equation for predicting VO2max . Intraclass coefficient with one-way ANOVA model was used to determine the test-retest reliability of the PACER. The results revealed that:(1) Concurrent validity of PACER was higher than the 800/1600m walk/run test.(PACER: r=.73& .80 ; 800/1600m walk/run test: r= -.64 & -.75, p<.05).(2) Test-retest reliability of the Pacer also yielded comparable results (intraclass correlation coefficient ; r=.72, p<.05). (3)According to stepwise regression equation of VO2max (criterion, ml·kg-1·min-1) from the PACER(predictors, laps )was ,VO2max= 0.447X1 -1.577X2 + 41.492(X1=laps X2=years). It is concluded that using Pacer test estimate cardiorespiratory endurance is as valid as 800/1600m walk/run test for junior high school students. |
英文摘要 |
The purpose of this study was to compare the PACER’s validity with 800/1600m walk/run test. Then we purpose to validate the test-retest reliability of PACER. Thirty-four subjects completed this study (20male, mean age: 14.35±0.88yrs, BMI: 20.10±3.14) and (14 male, mean age: 13.57±1.16yrs, BMI : 20.36±2.76). Each subjects randomized to performed the PACER, 800/1600m walk/run test and maximal exercise test through counter-balance design. Pearson’s productmoment correlation was used to compare the concurrent validity of PACER test to 800/1600m walk/run test ,and attempted to develop an equation for predicting VO2max . Intraclass coefficient with one-way ANOVA model was used to determine the test-retest reliability of the PACER. The results revealed that:(1) Concurrent validity of PACER was higher than the 800/1600m walk/run test.(PACER: r=.73& .80 ; 800/1600m walk/run test: r= -.64 & -.75, p<.05).(2) Test-retest reliability of the Pacer also yielded comparable results (intraclass correlation coefficient ; r=.72, p<.05). (3)According to stepwise regression equation of VO2max (criterion, ml·kg-1·min-1) from the PACER(predictors, laps )was ,VO2max= 0.447X1 -1.577X2 + 41.492(X1=laps X2=years). It is concluded that using Pacer test estimate cardiorespiratory endurance is as valid as 800/1600m walk/run test for junior high school students. |
主题分类 |
社會科學 >
體育學 |
参考文献 |
|
被引用次数 |
|