题名 |
以磁振造影技術分析腹部脂肪分佈之應用研究 |
并列篇名 |
An Analysis of Abdominal Adipose Tissue By Magnetic Resonance Imagine (MRI) |
DOI |
10.6222/pej.0037.200409.2405 |
作者 |
林瑞興(Jui-Hsing Lin);黃哲勳(Jer-Shyung Huang);蕭佳吉(Chia-Chi Hsiao);滕文豹(Wen-Bao Teng);方進隆(Chin-Lung Fang) |
关键词 |
腹部脂肪 ; 磁振造影 ; 內髒脂肪 ; 皮下脂肪 ; abdominal adipose tissue ; MRI ; visceral adipose tissue ; subcutaneous adipose tissue |
期刊名称 |
體育學報 |
卷期/出版年月 |
37期(2004 / 09 / 01) |
页次 |
47 - 56 |
内容语文 |
繁體中文 |
中文摘要 |
The purpose of this study was to examine the distribution of abdominal adipose tissue by magnetic resonance imaging (MRI). Thirty-six untrained healthy students (nineteen male and seventeen female) were recruited as subjects from the National Ping Tung Teachers College. All subjects were imaged on a 1.5 Tesla MRI (Signa Cvi, GE Medical System, Milwaukee, WI) scanner using a standard body coil at Kaohsiung Veterans General Hospital. The images were obtained 20 contiguous 10-mm axial Ti-weighted and set second image at the level of the umbilicus. All images were transferred to a personal computer using the Adobe Photoshop 7.0 and to calculate visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT) and total adipose tissue (TAT) deposition. The results showed that the correlation between pixel counts by automated computer method and personal designed software were significantly correlated (r=0.997, p<0.05). It showed that this method has acceptable precision. Also, the volumes obtained by the single umbilicus-level pixel and whole-abdominal fat were significantly correlated. (TAT r=0.91, SAT r=0.93, p<0.05). This showed that the single umbilicus-level image value was an excellent measure for whole-abdomen values in this cohort. Single umbilicus-level image is easier and less expensive. |
英文摘要 |
The purpose of this study was to examine the distribution of abdominal adipose tissue by magnetic resonance imaging (MRI). Thirty-six untrained healthy students (nineteen male and seventeen female) were recruited as subjects from the National Ping Tung Teachers College. All subjects were imaged on a 1.5 Tesla MRI (Signa Cvi, GE Medical System, Milwaukee, WI) scanner using a standard body coil at Kaohsiung Veterans General Hospital. The images were obtained 20 contiguous 10-mm axial Ti-weighted and set second image at the level of the umbilicus. All images were transferred to a personal computer using the Adobe Photoshop 7.0 and to calculate visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT) and total adipose tissue (TAT) deposition. The results showed that the correlation between pixel counts by automated computer method and personal designed software were significantly correlated (r=0.997, p<0.05). It showed that this method has acceptable precision. Also, the volumes obtained by the single umbilicus-level pixel and whole-abdominal fat were significantly correlated. (TAT r=0.91, SAT r=0.93, p<0.05). This showed that the single umbilicus-level image value was an excellent measure for whole-abdomen values in this cohort. Single umbilicus-level image is easier and less expensive. |
主题分类 |
社會科學 >
體育學 |
参考文献 |
|
被引用次数 |