英文摘要
|
Running speed variance by heart rate control (RSV(subscript HRC)) is a novel method to evaluate the cardiopulmonary fitness. Purpose: The study used two different methods of aerobic training on RSV(subscript HRC) and heart rate control (HRC) for eight weeks to compare the training effects of on cardiopulmonary fitness. Methods: Thirty-three college students (aged 19.8+1.8 years old, height 173.08+6.64 cm, weight 68.88+9.14 kg) were recruited into this study. By counter-balanced design, we tested them with a maximal oxygen uptake (VO2max) to obtain individual ventilatory threshold (VT), and the velocity of maximal oxygen intake (vVO2max). RSV(subscript HRC) of 80% maximal heart rate (80% HRmax) and HRmax were also obtained from each subject. We separated the subjects into three groups: HRC training (n=11), fixed speed running training (n=11), and control group (n=11) to carry on 8 weeks of aerobic training by treadmill for 30 minutes each time and 3 times a week. The training intensity of HRC group was set at 80% HRmax (80% max to 80% max-5bpm) and the training speed of fixed speed training group was set by individual RSV(subscript HRC). The control group did not do any training during this period. After eight weeks of training, all subjects were tested again with a maximal test and a RSV(subscript HRC). Results: RSVHRC, VO2max, VT, and v VO2max were improved by 21.43%, 9.77%, 9.57%, and 2.91% in RCV(subscript HRC), by 20.58%, 10.12%, 11.56%, and 12.55% in HRC group, and by 4.59%, -0.01%, -0.01%, and -3.3% in control group. There were significant training effects on both training groups as far as RSV(subscript HRC), VO2max, and VT is concerned. In addition, vVO2max improvement was also seen in HRC group. Conclusion: HRC training on 80%HRmax is an effective and safe method for aerobic training.
|
参考文献
|
-
王順正、吳顥照、王錠堯、林正常(2005)。單次間歇臨界速度測驗的效度研究。體育學報,38(2),1-12。
連結:
-
鄭景峰、林煉傑、黃憲鐘(2002)。八週有氧或肌力訓練對身體組成的影響。大專體育學刊,4(2),187-195。
連結:
-
Aunola, S.,Rusko, H.(1992).Does anaerobic threshold correlate with maximal lactate steady-state?.Journal of Sports Science,10(4),309-323.
-
Billat, V. L.,Flechet, B.,Petit, B.,Muriaux, G.,Koralsztein, J. P.(1999).Interval training at VO2max: Effects on aerobic performance and overtraining markers.Medicine and Science in Sports and Exercise,31(1),156-163.
-
Billat, V.,Lopes, P.,P. J. Maud,C. Foster (Eds.)(2006).Physiological assessment of human fitness.Champaign, IL:Human Kinetics.
-
Fox, E. L.,Bartels, R. L.,Billings, C. E.,O`Brien, R.,Bason, R.,Mathews, D. K.(1975).Frequency and duration of interval training programs and changes in aerobic power.Journal of Applied Physiology,38(3),481-484.
-
Jones, A. M.,Carter, H.,Doust, J. H.(1999).Effect of six weeks of endurance training on parameters of aerobic fitness.Medicine and Science in Sports and Exercise,31(5),280.
-
Matsumoto, T.,Ito, K.,Moritani, T.(1991).The relationship between anaerobic threshold and electromyographic fatigue threshold in college women.European Journal of Applied Physiology,63,1-5.
-
McConnell, T. R.(1988).Practical consideration in the testing of □O2max in runner.Sports Medicine,5(1),57-68.
-
Miller, J. M.,Housh, T. J.,Coburn, J. W.,Cramer, J. T.,Johnson, G. O.(2003).A proposed test for determining physical working capacity at the oxygen comsumption threshold.Medicine and Science in Sports and Exercise,35(5),275.
-
Moritani, T.,Nagata, A.,deVries, H. A.,Muro, M.(1981).Critical power as measure of physical work capacity and anaerobic threshold.Ergomomics,24(5),339-350.
-
Perry, S. R.,Housh, T. J.,Johnson, G. O.,Ebersole, K. T.,Bull, A. J.(2001).Heart rate and ratings of perceived exertion at the physical working capacity at the heart rate threshold.Journal of Strength and Conditioning Research,15(2),225-229.
-
Wagner, L. L.,Housh, T. J.(1993).A proposed test for determining physical working capacity at the heart rate threshold.Research Quarterly for Exercise and Sport,64(3),361-364.
-
Weir, L. L.,Weir, J. P.,Housh, T. J.,Johnson, G. O.(1997).Effect of an aerobic training rogram on physical working capacity at heart rate threshold.European Journal of Applied Physiology,75(4),351-356.
-
Young, C. C.,Morris, G. A.,Dempsey, R. L.,Virulhsri, P.,Ribar, M. A.,Gammons, M. R.(2004).The reproducibility of computerized heart rate monitoring as control for running studies.Medicine and Science in Sports and Exercise,36(5),26.
-
運動生理週訊
-
王順正、林必寧、王予仕、余奕德、黃彥鈞、陳信良、程文欣、吳忠芳(2005)。跑步機固定心跳率跑速變異的效度與信度研究。第四屆華人運動生理與體適能學者學會學術研討會論文集,臺灣:
-
王順正、林正常(1998)。呼吸循環穩定閾值的比較研究。我國大專運動科學86學年度研究獎助專刊,81-91。
-
王鶴森(1992)。臺北市,國立臺灣師範大學。
-
運動生理週訊
-
林必寧(2006)。嘉義縣,國立中正大學。
-
運動生理週訊
-
胡文瑜、謝旻宏、王予仕、黃彥鈞、王順正(2006)。2006體育運動學術團體聯合年會體育學術論文發表會。臺北市:
-
楊群正(2005)。嘉義縣,國立中正大學。
|