题名

Effect of Different Light-Curing Sources on Diametral Tensile Strength of Bulk Fill Composite Resins

作者

Yosi Kusuma Eriwati;Konita Nur Khasanah;Sefty Aryani Harahap;Siti Triaminingsih

关键词

Diametral tensile strength ; bulk fill composite resins ; LED ; QTH

期刊名称

Journal of International Dental and Medical Research

卷期/出版年月

11卷2期(2018 / 07 / 01)

页次

491 - 494

内容语文

英文

中文摘要

There are two common sources of light curing used to polymerize composite resins, the LED (Light Emitted Diode) and the QTH (Quartz Tungsten Halogen). This study aimed to evaluate the effect of using different light curing sources on diametral tensile strength of bulk fill composite resins. Three commercial bulk fill composite resins, Tetric N-Ceram Bulk Fill (Ivoclar-Vivadent, Liechtenstein, Germany), Beautifil-Bulk Restorative® (Shofu, Japan), and Filtek^(TM) Bulk-Fill (3MESPE, USA) were used to make disk specimens (6 mm in diameter, 3 mm in thickness) divided into two different polymerized groups (n=10), with LED for 20s and QTH for 40s light curing sources. Diametral tensile strength was tested using a Universal Mechanical Testing Machine (Shimadzu, Japan). Data were analyzed using one way ANOVA and Bonferonni post hoc tests. The results showed that diametral tensile strength mean value of all bulk fill composite resins polymerized using LED source were higher than QTH. There was no statistically difference between the group polymerized using LED and QTH (p ≥ 0.05), except in Filtek^(TM) Bulk-Fill group (p = 0.012). It can be concluded that different light-curing sources can influence the polimerization effect of Bulk-Fill composite resin in their diametral tensil strength properties.

主题分类 醫藥衛生 > 牙科與口腔科