This study compared the two step heights (35 cm vs. height adjusted according to the 90° knee angle) on the predictions of the VO2max predicted with their step indexes (SI) and steady heart rates (HR) during the test. Twenty-one college male students were the subjects (age: 21.71+0.45 years old, height: 174.7±7.1cm, weight: 69.9±8.1kg, VO2max: 45.41±1.30 ml/kg/min). VO2max was measured by the cycle ergometer with increasing workload. Participants performed respectively twice the step test which were divided into Fixed Height (FH: 35 cm) and Modified Height (MH: modification of the step height based on 90° knee angle). The frequency of the step test is 24 step/min for 3 minutes. The heart rate during exercise was measured to estimate HR, and the heart rate after exercise was measured to estimate SI. The results were as follows: First, correlation analyses between VO2max and the VO2max predicted by SI-FH and SI-MH were in significant (r=.469, p<.05; r=.681, p<.05). Second, correlation analyses between VO2max and the VO2max predicted by HR-FH 及HRMH were significant (r=-.626, p<.05; r=-.582, p<.05). Third, there was no difference between measured VO2max and predicted VO2max by SI-FH, SI-MH, HR-FH and HR-MH (p>.05). The correlation between VO2max and the VO2max predicted by SI of MH was higher than that of FH. The correlation between VO2max and the VO2max predicted by HR of FH was higher than that of MH. The step height adjusted according to the 90° knee angle can improve the validity to predict VO2max.

英文摘要

This study compared the two step heights (35 cm vs. height adjusted according to the 90° knee angle) on the predictions of the VO2max predicted with their step indexes (SI) and steady heart rates (HR) during the test. Twenty-one college male students were the subjects (age: 21.71+0.45 years old, height: 174.7±7.1cm, weight: 69.9±8.1kg, VO2max: 45.41±1.30 ml/kg/min). VO2max was measured by the cycle ergometer with increasing workload. Participants performed respectively twice the step test which were divided into Fixed Height (FH: 35 cm) and Modified Height (MH: modification of the step height based on 90° knee angle). The frequency of the step test is 24 step/min for 3 minutes. The heart rate during exercise was measured to estimate HR, and the heart rate after exercise was measured to estimate SI. The results were as follows: First, correlation analyses between VO2max and the VO2max predicted by SI-FH and SI-MH were in significant (r=.469, p<.05; r=.681, p<.05). Second, correlation analyses between VO2max and the VO2max predicted by HR-FH 及HRMH were significant (r=-.626, p<.05; r=-.582, p<.05). Third, there was no difference between measured VO2max and predicted VO2max by SI-FH, SI-MH, HR-FH and HR-MH (p>.05). The correlation between VO2max and the VO2max predicted by SI of MH was higher than that of FH. The correlation between VO2max and the VO2max predicted by HR of FH was higher than that of MH. The step height adjusted according to the 90° knee angle can improve the validity to predict VO2max.

主题分类 社會科學 > 體育學
参考文献
  1. American College of Sports Medicine(2000).ACSM`s guidelines for exercise testing and prescription.Philadelphia:Author.
  2. American College of Sports Medicine(2000).ACSM`s guidelines for exercise testing and prescription (6th ed.).Philadelphia:Author.
  3. Ariel, G.(1969).The effect of knee-joint angle on Harvard step-test performance.Ergonomics,12(1),33-37.
  4. Ashley, C. D.,Smith, J. F.,Reneau, P. D.(1997).A modified step test based on a function of subjects` stature.Perceptual and Motor Skills,85,987-993.
  5. Buckley, J. P.,Sim, J.,Eston, R. G.,Hession, R.,Fox, R.(2004).Reliability and validity of measures taken during the Chester step test to predict aerobic power and to prescribe aerobic exercise.British Journal of Sports Medicine,38(2),197-205.
  6. Cavanagh, P. R.,Kram, R.(1985).Mechanical and muscular factors affecting the efficiency of human movement.Medicine and Science in Sports and Exercise,17(3),326-31.
  7. Culpepper, M. I.,Francis, K.(1987).An anatomical model to determine step height in step testing for estimating aerobic capacity.Journal of Theoretical Biology,129(1),1-8.
  8. Francis, K.,Brasher, J.(1992).A height-adjusted step test for predicting maximal oxygen consumption in males.Journal of Sports Medicine and Physical Fitness,32(3),282-287.
  9. Francis, K.,Culpepper, M.(1989).Height-adjusted, rate-specific, single-stage step test for predicting maximal oxygen consumption.Southern Medical Journal,82(5),602-606.
  10. Ji, C. Y.(1993).Relationship between step test index and maximal aerobic capacity in female adolescents.Zhonghua Yu Fang Yi Xue Za Zhi,27(5),296-298.
  11. Laursen, P. B.,Shing, C. M.,Peake, J. M.,Coombes, J. S.,Jenkins, D. G.(2002).Interval training program optimization in highly trained endurance cyclists.Miedicine and Science in Sports and Exercise,34(11),1801-1807.
  12. Mazic, S.,Zivotic-Vanovic, M.,Igracki, I.,Zivanic, S.,Velkovski, S.(2001).A simple and reliable step-test for indirect evaluation of aerobic capacity.Medicinski Pregled,54(11;12),522-529.
  13. Mazic, S.,Zivotic-Vanovic, M.,Igracki, I.,Zivanic, S.,Velkovski, S.(2001).A simple and reliable step-test for indirect evaluation of aerobic capacity.Medicinski Pregled,54(2007/11/12),522-529.
  14. Santo, A. S.,Golding, L. A.(2003).Predicting maximum oxygen uptake from a modified 3-minute step test.Research Quarterly for Exercise and Sport,74(1),110-115.
  15. Shinno, N.,Tanaka, H.,Kamimura, M.,Toyoshima, Y.(1971).Management of the cruciate ligament in arthoplasty of the knee.Seikeigeka Orthopedic Surgery,22(4),306-310.
  16. Yoopat, P.,Vanwonterghem, K.,Louhevaara, V.(2002).Evaluation of a step-test for assessing the cardiorespiratory capacity of workers in Thailand: A pilot study.Journal of Human Ergology,31(1;2),33-40.
  17. Yoopat, P.,Vanwonterghem, K.,Louhevaara, V.(2002).Evaluation of a step-test for assessing the cardiorespiratory capacity of workers in Thailand: A pilot study.Journal of Human Ergology,31(2007/1/2),33-40.
  18. 王順正、林正常(1995)。登階測驗評估最大攝氧量的效度概化。體育學報,20,351-362。
  19. 薛淑琦(1992)。碩士論文(碩士論文)。桃園縣,國立體育學院運動科學研究所。
  20. 薛淑琦(1992)。桃園縣,國立體育學院運動科學研究所。
  21. 薛淑琦、李寧遠(1993)。登階測驗的類別。中華體育,7(2),86-96。
被引用次数
  1. 鄧政偉、楊昌斌、黃智能、邱新時(2018)。不同階高對三分鐘登階測驗體能指數之影響。嘉大體育健康休閒期刊,17(1),42-52。
  2. 黎俊彥、黃美雯、梁龍鏡(2007)。個案分析女子網球單打正式比賽之運動強度。運動生理暨體能學報,6,143-151。
  3. 梁龍鏡(2008)。大專女子網球單打與雙打正式比賽運動強度之個案分析。大專體育學刊,10(4),83-92。
  4. 林貴福、林全二(2012)。國小高年級女童心肺耐力測驗法之效度分析。文化體育學刊 ,14,35-45。
  5. 謝錦城、黎俊彥、林俊宏、朱斯鴻(2007)。氣喘幼童心肺功能測試模式之建立。大專體育學刊,9(3),117-126。