英文摘要
|
Acceptable quality of water filtered with reverse osmosis (RO) is a critical component for ensuring the health of hemodialysis patients. A routine water quality monitoring exercise conducted on 22 July 2016 found abnormal amounts of bacterial colonies and prompted the improvement program. Analysis of this assessment found that the primary issues were: ambiguous standards for RO conduit disinfection, lack of instruments to detect a high concentration of bleach, defective design of the water outlet for the water source, absence of auditing mechanisms and awareness among personnel. Remedial measures taken included: group meetings, acquiring RO system management experience of other hospitals through benchmarking, establishing conduit disinfection protocol, holding educational training, purchasing disinfectant concentration monitors, replacing water outlet to streamline the disinfection treatment process and generating a conduit disinfection verification checklist. The aim is to produce improved RO water quality that would reduce the abnormal rate of bacterial colonies (>50 cfu/ml) from 20% to 10%, to increase the precision rate of RO conduit disinfection process from 66.7% to 100%, and to increase the precision rate of water sampling process in RO bacterial monitoring from 83% to 100%. This project has effectively resolved RO water quality issues and achieved the improvement of the safety for hemodialysis patients. Relevant units may use this study for future reference.
|
参考文献
|
-
余秀芬,張麗娟(2016)。降低血液透析逆滲透水處理系統與透析液菌落數之專案。臺灣腎臟護理學會雜誌,15(1),11-25。
連結:
-
Hoenich N., Schwab S. J., & Sheridan A. M. (2016). Maintaining water quality for hemodialysis. Retrieved from http://www.uptodate.com/contents/maintaining-water-quality-forhemodialysis/print
-
Upadhyay, A.,Jaber, B. L.(2016).We use impure water to make dialysate for hemodialysis.Seminars in Dialysis,29(4),297-299.
-
台灣腎臟醫學會(2017,7 月 25 日).血液透析及腹膜透析訪視作業評量標準說明_106-107 年度_最終版_1060725.取自 http://www.tsn.org.tw/UI/F/F005.aspx
-
胡連順,黃正誼(2009)。如何維持透析液的品質。腎臟與透析,21(1),63-67。
-
黃淑鈴,蔡佳璋,陳美伶,黃小倩,姜遠萍,徐永堂,黃政文(2016)。血液透析之感染管制。腎臟與透析,28(2),101-105。
-
黃璉華,黃嗣棻(2013)。病人安全是醫療照護之首要。護理雜誌,60(2),13-18。
-
蔡佳璋,王婉菁,陳美伶,黃鳳雄,黃小倩,徐永堂,黃政文(2016)。血液透析用液品質之細菌監測。腎臟與透析,28(1),37-42。
-
蔡佳璋,王婉菁,陳美伶,葉庭豪,黃小倩,徐永堂,黃政文(2017)。血液透析室之逆滲透管路消毒監測。感染控制雜誌,27(4),176-182。
-
鄭輝賢(2008)。血液透析室之管路消毒經驗分享。腎臟與透析,20(2),121-123。
-
凃雅薰(2014)。建構血液透析安全的醫療環境-RO 水質內毒素。品質月刊,50(11),29-33。
|