题名

以慣性測量裝置應用於不同鞋子對跳遠運動表現之比較

并列篇名

A Comparison between Long Performances of Different Shoes by Using Inertial Measurement Units

DOI

10.6646/CYPEJ.2014.4.140

作者

黃貫倫(Kuan-Lun Huang);林國全(Guo-Chiuan Lin);呂惟帆(Wei-Fan Lu);何金山(Chin-Shan Ho)

关键词

慣性測量單元 ; 助跑頻率 ; 起跳時間 ; 支撐時間 ; Inertial Measurement Units ; Running Up Frequency ; Take-off Time ; Support Time

期刊名称

中原體育學報

卷期/出版年月

4期(2014 / 07 / 01)

页次

140 - 148

内容语文

繁體中文

中文摘要

目的:本研究目的主要藉由六自由度慣性測量單元探討不同鞋子在於助跑頻率、支撐、擺盪及起跳對於成績之影響。方法:以10名現役國中男性跳遠選手,測驗方式為穿著兩類田徑釘鞋與一般運動鞋在全程助跑各跳六次;實驗結果以SPSS 20.0統計軟體進行成對樣本T檢定分析(Paired-Samples T Test)。結果:分析結果顯示步頻時間、支撐時間、擺盪時間皆無差異相關分析部分(p>.05),而起跳時間與跳遠成績皆達顯著差異(p<.05)。結論:從結果中可知,透過六自由度慣性測量單元能讓教練即時辨識運動員在訓練上更細微的動作以達到更有效率的訓練模式,並期望可做為未來在訓練上與選才方法做為參考依據。

英文摘要

Purpose: The purpose of this study was to investigate the difference between spiked shoes and running shoes on running up frequency, support time, foot swing time, takeoff time, and grades in long jump by using inertial measurement units. Methods: Ten junior high school long jump athletes were recruited in present study. All the subjects performed six times long jump by wearing spiked shoes and running shoes respectively. And the IMUs were equipped on the forefeet of the shoes. Paired-Samples T Test was used to test the difference between different shoes. Results: The statistical results indicated that there were no significant differences between shoes in running up frequency, support time, and foot swing time. And the takeoff time and grades were significant shorter by wearing spiked shoes. Conclusion: According the results, the IMU could measure the slight changes of movement pattern of athlete. The coaches can use the IMU as a referee to train effectively. In the future, this device might be used in talent selection in sports and training.

主题分类 社會科學 > 體育學
参考文献
  1. 相子元、石又、何金山(2012)。感測科技於運動健康科學之應用。體育學報,45(1),1-12。
    連結:
  2. 高崇壽、黃長福(2007)。不同項目選手在跳遠踏板起跳腳運動生物力學分析。運動教練科學,8,57-65。
    連結:
  3. 廖焜福、林學宜、陳浚良、陳奕良(2012)。如何選擇羽球鞋。大專體育,118,63-71。
    連結:
  4. Ayusawa, K.,Nakamura, Y.,Venture, G.(2009).Optimal estimation of human body segmentation dynamics using realtime visual feedback.Proceeding of the IEEE/RSJ International Conf.
  5. Ayusawa, K.,Venture, G.,Nakamura, Y.(2011).Real-time implementation of physically consistent identification of human body segments.Robotics and Automation (ICRA), 2011 IEEE International Conference
  6. Bergmann, J. H.,Mayagoitia, R. E.,Smith, I. C.(2009).A portable system for collecting anatomical joint angles during stair ascent: a comparison with an optical tracking device.Dynamic Medicine,8(1),3.
  7. Bouten, C. V.,Koekkoek, K. T.,Verduin, M.,Kodde, R.,Janssen, J. D.(1997).A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity.Biomedical Engineering, IEEE Transactions on,44(3),136-147.
  8. Burton, A.W.,Miller, D. E.(1998).Movement skill assessment.Champaign, IL:Human Kinetics.
  9. Callaway, A. J.,Cobb, J. E.,Jones, I.(2009).A comparison of video and accelerometer based approaches applied to performance monitoring in swimming.International Journal of Sports Science and Coaching,4(1),139-153.
  10. Casartelli, N.,Muller, R.,Maffiuletti, N. A.(2010).Validity and reliability of the myotest accelerometric system for the assessment of vertical jump height.The Journal of Strength & Conditioning Research,24(11),3186-3193.
  11. Chen, K. Y.,Bassett, D. R.(2005).The technology of accelerometry-based activity monitors: current and future.Medicine and science in sports and exercise,37(11),S490.
  12. Clayton, J.(1992).Jumping Event: Similarities-Difference.Track & Field Quarterly Review,92(4),1-3.
  13. Hunter, J. P.,Marshall, R. N.,McNair, P. J.(2004).Interaction of step length and step rate during sprint running.Medicine and science in sports and exercise,36(2),261-271.
  14. Kinomura, Y.,Muraki, Y.,Zushi., K.(2012).Take-off motion for jumping with an increase in the number of steps in the approach run for the long jump: focusing on the rate of change of take-off action from a short to a long approach jump.Japanese Journal of Physical Education and Sport Science,57(1),71-82.
  15. Kraemer, W.(2010).Construct validity of the Myotest in measuring force and power production.J Strength Cond Res,24,1.
  16. Langendorfer, S.J.(2001).Comparing three methods for estimating rater objectivity.Journal of Sport & Exercise Psychology,23,58-59.
  17. Lim, K. Y.,Goh, F. Y. K.,Dong, W.,Nguyen, K. D.,Chen, I. M.,Yeo, S. H.,Kim, C. G.(2008).A wearable, self-calibrating, wireless sensor network for body motion processing.Robotics and Automation, 2008. ICRA 2008. IEEE International Conference
  18. Pappas, I. P.,Popovic, M. R.,Keller, T.,Dietz, V.,Morari, M.(2001).A reliable gait phase detection system.Neural Systems and Rehabilitation Engineering, IEEE Transactions,9(2),113-125.
  19. Sato, K.,Smith, S. L.,Sands, W. A.(2009).Validation of an accelerometer for measuring sport performance.The Journal of Strength & Conditioning Research,23(1),341-347.
  20. Shih, Y.,Shiang, T. Y.(2010).Measuring foot pronation during running by using gyro sensor.The 14th China Sports Biomechanics Academic Conference,Jinan, China:
  21. Silva, P.,Mota, J.,Esliger, D.,Welk, G.(2010).Technical reliability assessment of the Actigraph GT1M Accelerometer.Measurement in Physical Education and Exercise Science,14(2),79-91.
  22. Stefanyshyn, D.,Fusco, C.(2004).Athletics: Increased shoe bending stiffness increases sprint performance.Sports Biomechanics,3(1),55-66.
  23. Venture, G.,Ayusawa, K.,Nakamura, Y.(2008).Motion capture based identification of the human body inertial parameters.Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE
  24. Weyand, P. G.,Sternlight, D. B.,Bellizzi, M. J.,Wright, S.(2000).Faster top running speeds are achieved with greater ground forces not more rapid leg movements.Journal of applied physiology,89(5),1991-1999.
  25. Yang, S.,Li, Q.(2012).IMU-based ambulatory walking speed estimation in constrained treadmill and overground walking.Computer methods in biomechanics and biomedical engineering,15(3),313-322.
  26. Zhu, W.,Cole, E. L.(1996).Many-faceted Rasch calibration of a gross motor instrument.Research quarterly for exercise and sport,67(1),24-34.
  27. 王錫鈞(2009)。碩士論文(碩士論文)。台北市,臺北市體育學院運動器材研究所。
  28. 林昆鋒、許瓊云、陳景雲、林寶城(2009)。不同慢跑鞋鞋底紋路摩擦現象之探討。第十三屆全國運動生物力學學術交流大會,浙江:
  29. 陳弘仁(2012)。微機電系統的市場發展現況及未來趨勢。奈米通訊,19,3。