中文摘要
|
研究目的為透過實際測定數據來探討二氧化碳監測之意義與應用,並結合法規與文獻探討二氧化碳監測之預期意義。依據職業安全衛生法要求,事業單位在作業場所必須進行二氧化碳濃度監測,就現有二氧化碳監測要求規範下,事業單位如何進行二氧化碳監測並將監測結果轉化為有意義的數據提供作業環境管理參考。研究方法將透過特定場所及模擬實驗暴露腔進行長時間監測二氧化碳濃度變化,依據二氧化碳濃度隨時間變化情形,檢討二氧化碳監測時應注意事項,最後再依據監測數據及文獻資料,探討如何應用監測結果來改善作業環境。研究結果發現二氧化碳監測數據會受時間與空間之影響,應該擬定適當監測策略,才能顯示環境中有意義的二氧化碳濃度狀況。而常見之二氧化碳監測數據為監測人員呼氣所產生之二氧化碳於環境中累積情形,文獻顯示最高濃度約為3,300ppm,平均濃度約為2,250ppm,發生在學生上課教室內。二氧化碳監測數據不應只應用於「勞工暴露狀況評估」,除非作業場所在人員呼氣外仍有其它二氧化碳發生源,二氧化碳監測結果連結於容許濃度標準才有意義,事業單位也應將二氧化碳監測數據應用於「掌握勞工作業環境實態」之另一目的,應用此來管理作業場所通風換氣狀況,若超過設定濃度,就應該對作業場所之換氣狀況進行評估改善,符合作業場所對於新鮮空氣換氣之要求。
|
英文摘要
|
According to Enforcement Rules of the Occupational Safety and Health Act, a business unit has to detect carbon dioxide concentration in some workplace. It is often being questioned that whether this detection is necessary or not, because the detecting result shows that the carbon dioxide concentration is always under the standard. Although there are some arguments in carbon dioxide concentration assessment, the labors are familiar with the information about carbon dioxide. Therefore, it still needs to be discussed and taken it seriously. This research uses experiment to discuss the meaning of carbon dioxide assessment and its' application, and combining with legislation and literature to discuss the expected meaning of carbon dioxide. Otherwise, this research also offers a business unit as an operating environment reference that how to do carbon dioxide assessment and turn the research result into another meaning in the regulation of carbon dioxide assessment. This study tests a special situation in a long time, including in some particular place and simulation chamber, and observes the changing of carbon dioxide concentration. By following the changing of carbon dioxide concentration, it can confirm the notice of carbon dioxide assessment again. At last, combining with research data and literature, and discuss that how to use this assessment result to prove operating environment. The research shows that assessment data of carbon dioxide can be influenced when changing time and space. It should be formulated an appropriate strategy and it may be shown a meaningful result. Normally, the data of carbon dioxide assessment was defined by the accumulation of carbon dioxide that employee breathe in working place. In literature, the highest carbon dioxide concentration is 3,300 ppm, and the average carbon dioxide concentration is 2,250 ppm in the student classroom. It shows that the lone time average carbon dioxide concentration will not be over 5,000 ppm, and we can forecast that in working place may have the same result. It's meaningful that concerning another source of carbon dioxide in working place without employee's breathing, and it also can connect with assessment data and the standard of concentration. The other thing is carbon dioxide can be used that understanding labors' operating environment, and manage working place ventilation. If the concentration is over the standard, the business unit has to do carbon dioxide assessment again to make sure that whether the rate of exchange fresh air is corresponded with the standard.
|
参考文献
|
-
Lu, Po-Hung,Chen, Chun-Wan,Chang, Cheng-Ping(2006).Accumvlation of CO from Gas Water Heater on Balconies.Journal of Occupational Safety and Health,14,299-307.
連結:
-
勞動部。職業安全衛生法施行細則;2014。
-
勞動部。職業安全衛生設施規則;2014。
-
(1999).OSHA. OSHA Technical Manual (OTM) Section III.Washington:The Institute.
-
日本厚生勞動省。作業環境測定基準;2007。
-
行政院環保署。室內空氣品質管理法;2011。
-
勞動部。勞工作業環境監測實施辦法。臺灣省臺北市;2013。
-
勞動部。勞工作業場所容許暴露標準;2014。
-
Echt, Alan,Burroughs, G.E.,Lenhart, Steven W.,Booher, Donald E(1996).,Cincinnati, Ohio:Cincinnati Sportsmedicine and Orthopaedic Center.
-
Harper, Peter(2010).,未出版
-
Health and Safety Executive(2011).EH40/2005 Workplace exposure limits-Containing the list of workplace exposure limits for use with the Control of Substances Hazardous to Health Regulations 2002 (as amended).
-
OSHA(1999).OSHA Technical Manual (OTM) Section II.Washington:The Institute.
-
The National Institute for Occupational Safety and Health=NIOSH(1967).Criteria for a Recommended Standard: Occupational Exposure to Carbon Dioxide.Atlanta:The Institute.
-
U.S. Environmental Protection Agency(2000).Carbon Dioxide as a Fire Suppressant: Examining the Risks.
-
Walsh, Peter,Hemingway, Michael,Rimmer, Duncan(2013).,未出版
-
朴允鎬(1999)。碩士論文(碩士論文)。國立臺灣大學環境工程學研究所。
-
李彥頤(2004)。博士論文(博士論文)。國立成功大學建築學系。
-
洪增淵(2004)。碩士論文(碩士論文)。朝陽科技大學環境工程與管理系。
-
徐玉琴(2013)。碩士論文(碩士論文)。國立高雄第一科技大學環境與安全衛生工程研究所。
-
馬雪惠(2014)。碩士論文(碩士論文)。國立雲林科技大學營建工程系。
-
張耀鍾(2004)。碩士論文(碩士論文)。國立台北科技大學環境規劃與管理研究所。
-
陳春萬、鍾基強(2000)。整體換氣指標與換氣率ACH關係之研究。動部勞動及職業安全衛生研究所。
-
陳鴻嶽(2013)。碩士論文(碩士論文)。國立勤益科技大學冷凍空調系。
-
粘金傳(2011)。碩士論文(碩士論文)。大葉大學工學院。
-
黃志明(1993)。碩士論文(碩士論文)。國立成功大學建築研究所。
-
葉耀文(2008)。碩士論文(碩士論文)。國立台北科技大學環境工程與管理研究所。
-
鄭安邑(2014)。碩士論文(碩士論文)。輔仁大學公共衛生學系。
-
薛志超(2013)。碩士論文(碩士論文)。大仁科技大學環境管理研究所。
-
鍾育泰(2007)。碩士論文(碩士論文)。中華大學土木與工程資訊學系。
|