進行人工植牙治療時,需先評估要植牙區域的顎骨骨密度。評估的方式可以分為以放射線影像和手術中得到的觸感進行評估。因為牙位區域的不同而有差異;其中第四類骨質最常分佈於上顎後牙區。雖然在低骨密度區域進行牙科植體治療有著較高的風險,但是選擇適當的治療方式有助於得到臨床可接受的結果及預後。在臨床考量上,建議選用有做表面處理,粗糙表面且有較大直徑的牙科植體;在植牙手術適時地進行較少量的骨修磨,並延長癒合時間。

主题分类 醫藥衛生 > 基礎醫學
醫藥衛生 > 社會醫學
参考文献
  1. Alghamdi, H,Anand, PS,Anil, S(2011).Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study.J Oral Maxillofac Surg,69,506-512.
  2. d'Avila, S,dos Reis, LD,Piattelli, A(2010).Impact of smoking on human bone apposition at different dental implant surfaces: a histologic study in type IV bone.J Oral Implantol,36,85-90.
  3. Friberg, B,Sennerby, L,Meredith, N(1999).A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study.Int J Oral Maxillofac Surg,28,297-303.
  4. Fuh, LJ,Huang, HL,Chen, CS(2010).Variations in bone density at dental implant sites in different regions of the jawbone.J Oral Rehabil,37,346-351.
  5. Goiato, MC,dos Santos, DM,Santiago, JF, Jr(2014).Longevity of dental implants in type IV bone: a systematic review.Int J Oral Maxillofac Surg,43,1108-1116.
  6. Hutton, JE,Heath, MR,Chai, JY(1995).Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Branemark implants.Int J Oral Maxillofac Implants,10,33-42.
  7. Khang, W,Feldman, S,Hawley, CE(2001).A multi-center study comparing dual acid-etched and machined-surfaced implants in various bone qualities.J Periodontol,72,1384-1390.
  8. Misch, CE(1993).Progressive loading of bone with implant prostheses.J Dent Symp,1,50-53.
  9. Misch, CE(2004).Dental Implant Prosthetics.Philadelphia:Elsevier Health Sciences.
  10. Misch, CE(1990).Density of bone: effect on treatment plans, surgical approach, healing, and progressive boen loading.Int J Oral Implantol,6,23-31.
  11. Mohlhenrich, SC,Heussen, N,Elvers, D(2015).Compensating for poor primary implant stability in different bone densities by varying implant geometry: a laboratory study.Int J Oral Maxillofac Surg,44,1514-1520.
  12. Östman, PO,Hellman, M,Sennerby, L(2005).Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion.Clin Implant Dent Relat Res,7,60-69.
  13. Rocci, A,Martignoni, M,Gottlow, J(2003).Immediate loading of Branemark System TiUnite and machined-surface implants in the posterior mandible: a randomized open-ended clinical trial.Clin Implant Dent Relat Res,5,57-63.
  14. Sennerby, L,Andersson, P,Verrocchi, D(2012).One-year outcomes of Neoss bimodal implants. A prospective clinical, radiographic, and RFA study.Clin Implant Dent Relat Res,14,313-320.
  15. Stach, RM,Kohles, SS(2003).A meta-analysis examining the clinical survivability of machined-surfaced and osseotite implants in poor-quality bone.Implant Dent,12,87-96.
  16. Trisi, P,Lazzara, R,Rao, W(2002).Bone-implant contact and bone quality: evaluation of expected and actual bone contact on machined and osseotite implant surfaces.Int J Periodontics Restorative Dent,22,535-545.
  17. Trisi, P,Rao, W(1999).Bone classification: clinical-histomorphometric comparison.Clin Oral Implants Res,10,1-7.
  18. Weng, D,Hoffmeyer, M,Hürzeler, MB(2003).Osseotite vs. machined surface in poor bone quality. A study in dogs.Clin Oral Implants Res,14,703-708.
  19. Zarb, GA(1985).Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry.Chicago:Quintessence Pub Co.
  20. 陳佳惠(2013)。高雄醫學大學牙醫學研究所。