聚乙烯俗稱塑膠,主要分有低密度聚乙烯與高密度聚乙烯,而醫界懂得利用塑膠來開發人工髖關節墊片之後,人工髖關節手術自此開始獲得巨大的成功。雖然如此,人工髖關節在使用若干時日之後,墊片磨耗的問題還是造成了植入物的失效而需要再置換,開發更耐磨的人工髖關節便是目前臨床醫學最重要的課題之一。各個超耐磨墊片的臨床報告紛紛被發表,而超耐磨墊片是否能有效的降低重開率雖然並沒有一致的報告,但是利用超耐磨墊片來開發更符合人體原始結構的人工髖關節則是未來的趨勢。

主题分类 醫藥衛生 > 基礎醫學
醫藥衛生 > 社會醫學
参考文献
  1. American Chemical Society National Historic Chemical Landmarks. Polypropylene and High-density Polyethylene.< https://www.acs.org/content/acs/en/education/whatischemistry/landmarks/polypropylene.html>
  2. polyethylene W-cl.
  3. (2007).Wellcome Witnesses to Twentieth Century Medicine.Wellcome Trust Centre for the History of Medicine at UCL..
  4. Wiki-NonWovenFabric. < https://en.wikipedia.org/wiki/Nonwoven_fabric>
  5. Wiki-polyethylene.
  6. (2005).Encyclopedia of Chemical Processing.
  7. ASTM(2014).Standard Specification for Ultra-High-Molecular-Weight Polyethylene Powder and Fabricated Form for Surgical Implants.West Conshohocken:ASTM International.
  8. Babovic, N,Trousdale, RT(2013).Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up.J Arthroplasty,28,815-817.
  9. Bedard, NA,Callaghan, JJ,Stefl, MD(2014).Fixation and wear with a contemporary acetabular component and cross-linked polyethylene at minimum 10-year follow-up.J Arthroplasty,29,1961-1969.
  10. Bracco, P,Bellare, A,Bistolfi, A(2017).Ultra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review.Materials,10,791.
  11. Campbell, DG,Field, JR,Callary, SA(2010).Second-generation highly cross-linked X3™ polyethylene wear: a preliminary radiostereometric analysis study.Clin Orthop Relat Res,468,2704-2709.
  12. Charnley, J(1963).Tissue Reactions to Polytetrafluorethylene.Lancet,282,1379.
  13. Chmell, MJ,Poss, R,Thomas, WH(1996).Early failure of hylamer acetabular inserts due to eccentric wear.J Arthroplasty,11,351-353.
  14. D'Antonio, JA,Manley, MT,Capello, WN(2005).Five-year experience with Crossfire highly cross-linked polyethylene.Clin Orthop Relat Res,441,143-150.
  15. Devane, PA,Horne, JG,Ashmore, A(2017).Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty: A 10-Year Double-Blinded Randomized Controlled Trial.J Bone Joint Surg Am,99,1703-1714.
  16. Dumbleton, JH,D'Antonio, JA,Manley, MT(2006).The basis for a second-generation highly cross-linked UHMWPE.Clin Orthop Relat Res,453,265-271.
  17. Engh, CA, Jr,Hopper, RH, Jr,Huynh, C(2012).A prospective, randomized study of cross-linked and non-cross-linked polyethylene for total hip arthroplasty at 10-year follow-up.J Arthroplasty,27,2-7.
  18. García-Rey, E,García-Cimbrelo, E,Cruz-Pardos, A(2013).New polyethylenes in total hip replacement: A ten- to 12-year follow-up study.Bone Joint J,95,326-332.
  19. Glyn-Jones, S,Thomas, GE,Garfjeld-Roberts, P(2015).The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.Clin Orthop Relat Res,473,432-438.
  20. Glyn-Jones, S,Thomas, GER,Garfjeld-Roberts, P(2015).The John Charnley Award: Highly Crosslinked Polyethylene in Total Hip Arthroplasty Decreases Long-term Wear: A Double-blind Randomized Trial.Clinical Orthopaedics and Related Research®,473,432-438.
  21. Gomez, PF,Morcuende, JA(2005).A historical and economic perspective on Sir John Charnley, Chas F. Thackray Limited, and the early arthoplasty industry.Iowa Orthop J,25,30-37.
  22. Green, TR,Fisher, J,Stone, M(1998).Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro.Biomaterials,19,2297-2302.
  23. Greiner, JJ,Callaghan, JJ,Bedard, NA(2015).Fixation and Wear With Contemporary Acetabular Components and Cross-Linked Polyethylene at 10-Years in Patients Aged 50 and Under.J Arthroplasty,30,1577-1585.
  24. Hanna, SA,Somerville, L,McCalden, RW(2016).Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years' follow-up.Bone Joint J,98(B),28-32.
  25. Hopper, RH, Jr,Ho, H,Sritulanondha, S(2018).Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene.Clin Orthop Relat Res,476,279-290.
  26. Johanson, P-E,Digas, G,Herberts, P(2012).Highly Crosslinked Polyethylene Does Not Reduce Aseptic Loosening in Cemented THA 10-year Findings of a Randomized Study.Clinical Orthopaedics and Related Research®,470,3083-3093.
  27. Karidakis, GK,Karachalios, T(2015).Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.Clin Orthop Relat Res,473,3836-3845.
  28. Kurtz, SM(ed.)(2004).The UHMWPE Handbook.San Diego:Academic Press.
  29. Kurtz, SM(ed.)(2016).UHMWPE Biomaterials Handbook.Oxford:William Andrew Publishing.
  30. Kurtz, SM,Austin, MS,Azzam, K(2010).Mechanical properties, oxidation, and clinical performance of retrieved highly cross-linked Crossfire liners after intermediate-term implantation.J Arthroplasty,25,614-623.
  31. Kurtz, SM,Gawel, HA,Patel, JD(2011).History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.Clin Orthop Relat Res,469,2262-2277.
  32. Kurtz, SM,Muratoglu, OK,Evans, M(1999).Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty.Biomaterials,20,1659-1688.
  33. Lachiewicz, PF,Soileau, ES(2016).Highly Cross-linked Polyethylene Provides Decreased Osteolysis and Reoperation at Minimum 10-Year Follow-Up.J Arthroplasty,31,1959-1962.
  34. Livingston, BJ,Chmell, MJ,Spector, M(1997).Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner.J Bone Joint Surg Am,79,1529-1538.
  35. Matsubara, K,Watanabe, M(1967).The wear properties of high-density polyethylene irradiated by gamma rays.Wear,10,214-222.
  36. Oparaugo, PC,Clarke, IC,Malchau, H(2001).Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature.Acta Orthop Scand,72,22-28.
  37. Orishimo, KF,Claus, AM,Sychterz, CJ(2003).Relationship Between Polyethylene Wear and Osteolysis in Hips witha Second-Generation Porous-Coated Cementless Cup After Seven Years of Follow-up.JBJS,85,1095-1099.
  38. Paxton, E,Cafri, G,Havelin, L(2014).Risk of revision following total hip arthroplasty: metal-on-conventional polyethylene compared with metal-on-highly cross-linked polyethylene bearing surfaces: international results from six registries.J Bone Joint Surg Am,96,19-24.
  39. Sakoda, H,Voice, AM,McEwen, HM(2001).A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.J Arthroplasty,16,1018-1023.
  40. Schmalzried, TP,Campbell, P,Schmitt, AK(1997).Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements.J Biomed Mater Res,38,203-210.
  41. Shen, C,Tang, ZH,Hu, JZ(2014).Does cross-linked polyethylene decrease the revision rate of total hip arthroplasty compared with conventional polyethylene? A meta-analysis.Orthop Traumatol Surg Res,100,745-750.
  42. Thangaraj, R,Kuiper, J,Perkins, RD(2019).Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.J Clin Orthop Trauma,10,350-357.
  43. Tsukamoto, M,Mori, T,Ohnishi, H(2017).Highly Cross-Linked Polyethylene Reduces Osteolysis Incidence and Wear-Related Reoperation Rate in Cementless Total Hip Arthroplasty Compared With Conventional Polyethylene at a Mean 12-Year Follow-Up.J Arthroplasty,32,3771-3776.
  44. Tsukamoto, M,Mori, T,Ohnishi, H(2017).Highly Cross-Linked Polyethylene Reduces Osteolysis Incidence and Wear-Related Reoperation Rate in Cementless Total Hip Arthroplasty Compared With Conventional Polyethylene at a Mean 12-Year Follow-Up.J Arthroplasty,32,3771-3776.
  45. Tsukamoto, M,Ohnishi, H,Mori, T(2017).Fifteen-Year Comparison of Wear and Osteolysis Analysis for Cross-Linked or Conventional Polyethylene in Cementless Total Hip Arthroplasty for Hip Dysplasia-A Retrospective Cohort Study.J Arthroplasty,32,161-165.
  46. Valstar, ER,Gill, R,Ryd, L(2005).Guidelines for standardization of radiostereometry(RSA) of implants.Acta orthopaedica,76,563-572.
  47. Ward, C(2009).History of self-experimentation in orthopaedics.Iowa Orthop J,29,127-129.
  48. Wroblewski, BM,Siney, PD,Fleming, PA(1999).Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report.J Bone Joint Surg Br,81,54-55.