题名

500kW_t鈣迴路捕碳程序中碳酸化系統形式及煅燒條件對捕碳效益之影響

并列篇名

Effects of Carbonator Design and Calcination Condition on the Carbon Capture Performance in a 500kWt Calcium Looping Carbon Capture Process

DOI

10.29911/JEHVACE_NEW.202103_(126).0006

作者

周揚震(Yiang-Chen Chou);黃欽銘(Chin-Ming Huang);陳威丞(Wei-Cheng Chen);徐恆文(Heng-Wen Hsu);萬皓鵬(Hou-Peng Wan)

关键词

鈣迴路捕碳程序 ; 挾帶床碳酸化系統 ; 多階旋風式碳酸化系統 ; 捕碳效率 ; 煅燒效率 ; 粉體輸送 ; Calcium Looping Process ; Entrained-Bed Carbonator ; Cascade Cyclone Carbonator ; Carbon Capture Efficiency ; Calcination Efficiency ; Sorbent Transportation

期刊名称

冷凍空調&能源科技

卷期/出版年月

126期(2021 / 03 / 10)

页次

62 - 68

内容语文

繁體中文

中文摘要

本研究測試500kWt鈣迴路系統中,挾帶床式與多階旋風式碳酸化系統對全系統運轉穩定性及二氧化碳捕獲之影響;並以測試結果為依據,釐清操作條件對煅燒系統穩定性及吸附劑再生特性之影響。實驗結果顯示:挾帶床碳酸化系統雖可達到粉體循環之目的,但挾帶床碳酸化系統碳酸化反應放熱不顯著,使反應器內溫度低於碳酸化最佳溫度(500-650℃)。旋風塔碳酸化系統可維持較高溫度有助於進行碳酸化反應。於測試期間可連續運轉52.1小時捕獲二氧化碳且捕碳效率約43%;若調整柴油使用量及迴流風車轉速,會改變煅燒系統內之輸入熱量、溫度分布及煙氣體積流率,進而影響煅燒效率、粉體輸送效率及粉體分離效率。透過操作參數調整,可再生出高反應特性之吸附劑,有助於二氧化碳捕獲反應。

英文摘要

The aim of this study is to investigate effects of carbonator designs and calcination conditions on the system stability and carbon capture efficiency in a 500 kWt calcium looping carbon capture system. Experimental results indicated that the heat transfer in the entrained-bed carbonator was insufficient, leading to the flue gas temperature did not achieve the optimal carbonation temperature. 43% carbon capture efficiency for 52.1 hours was achieved in the cascade cyclone carbonator because the elevated temperature inside reactor accelerated the carbonation rate. The amount of input thermal energy and flue gas recirculation rate significantly affected the temperature profile and heat transfer phenomena inside calciner, as well as altering sorbent calcination efficiency, and solid transportation and separation efficiencies. The sorbents with no surface sintering and calcination efficiencies higher than 85% were achieved for experiments conducted under suitable conditions in this study.

主题分类 工程學 > 電機工程
参考文献
  1. Chang, M.H.,Chen, W.C.,Huang, C.M.,Liu, W.H.,Chou, Y.C.,Chang, W.C.,Chen, W.,Cheng, J.Y.,Huang, K.E.,Hsu, H.W.(2014).Design and Experimental Testing of a 1.9MWth Calcium Looping Pilot Plant.Energy Procedia,63,2100-2108.
  2. Chou, Y.C.,Chen, W.C.,Hsu, H.W.,Wan, H.P.(2018).Study on Sorbent Transportation in a 500 kWt Cascade Cyclone Calciner.2018 Annual Meeting of the Taiwan Filtration and Separations Society and International Advanced Filtration Technology Congress,Taipei, Taiwan:
  3. International Energy Agency(2017).Energy Technology Perspectives 2017.
  4. 周揚震,陳威丞,徐恆文,萬皓鵬(2018)。500kWt多階旋風式系統內之粉體輸送對煅燒效率之影響。第 30 屆環境工程學會年會空氣污染控制技術研討會,台南,台灣:
  5. 周揚震,陳威丞,黃欽銘,徐恆文,萬皓鵬(2019)。鈣迴路二氧化碳捕獲系統穩定運轉示範驗證。108 年綠色技術與工程實務研討會,台北,台灣:
  6. 周揚震,陳威丞,黃欽銘,徐恆文,萬皓鵬(2018)。多階旋風式二氧化碳捕系統吸附劑再生之操作特性研究。中華民國第二十八屆燃燒與能源學術研討會,新竹,台灣:
  7. 周揚震,黃欽銘,陳威丞,徐恆文,萬皓鵬(2019)。500kWt 鈣迴路煅燒系統穩定性之研究。台灣過濾與分離學會年會,台北,台灣:
  8. 黃欽銘,張名惠,陳瑞燕,陳威丞,周揚震,徐恆文,萬皓鵬(2018)。500kWth 鈣循環二氧化碳捕獲廠多階旋風式火段燒系統研究。燃燒季刊,4,25-41。