中文摘要

為提升我國玻璃門冷藏櫃之能效表現與均溫性,本研究盤點歐洲、美國、日本、澳洲與中國合計1,746台玻璃門冷藏櫃之資訊,針對各設計參數進行分析,如:冷櫃形式、隔熱材厚度、回風距離及冷媒使用等,提供各國產品設計值作為我國玻璃門冷藏櫃之設計範圍參考,也針對玻璃門冷櫃常出現之短循環、外部熱入侵等痛點給予改善建議。

英文摘要

To improve the power consumption and temperature non-uniformity of domestic closed refrigerated display cabinets (CRDCs), of which the performance analysis and improvement suggestions are discussed in this study. Totally 1,746 CRDCs-related data collected from Europe, U. S., Japan, Australia, and China were classified to figure out the design trends. Four parts of the CRDC are studied (e.g. the formation of CRDCs, the thickness of insulation material, the distance for circulation of airflow, and the filled refrigerant), then summarized as references for developing high performance domestic products. Also, the solution for short circulation of airflow or external heat intrusion, commonly shown in the CRDCs, is provided in this study.

主题分类 工程學 > 電機工程
参考文献
  1. https://energiforskning.dk/en/node/15931
  2. https://climate.ec.europa.eu/eu-action/fluorinated-greenhouse-gases/eu-legislation-control-f-gases_en
  3. https://www.coolingpost.com/world-news/emerson-extends-r290-compressor-offering/
  4. (2016).La Revue Pratique du Froid et du Conditionnement d'Air.St-Just-la-Pendue:Imprimerie Chirat.
  5. Anastase, A.,Tarlea, G. M.(2021).Refrigeration theoretical comparison between European condensing units.IOP Conference Series: Earth and Environmental Science,664(1),012080.
  6. CARBON TRUST(2010).Refrigeration Road Map.
  7. Lindberg, U.(2010).Vertical display cabinets without and with doors-a comparison of measurements in a laboratory and in a supermarket.1st IIR Conference on Sustainability and the Cold Chain
  8. Mota-Babiloni, A.,Navarro-Esbrí, J.,Peris, B.,Molés, F.,Verdú, G.(2015).Experimental evaluation of R448A as R404A lower-GWP alternative in refrigeration systems.Energy Conversion and Management,105,756-762.
  9. Salehy, Y.,Hoang, H. M.,Cluzel, F.,Leroy, Y.,Delahaye, A.,Fournaison, L.,Yannou, B.(2020).Energy performances assessment for sustainable design recommendations: Case study of a supermarket's refrigeration system.Procedia CIRP,90,328-333.
  10. Shilliday, J. A.,Tassou, S. A.,Shilliday, N.(2009).Comparative energy and exergy analysis of R744, R404A and R290 refrigeration cycles.International Journal of Low-Carbon Technologies,4(2),104-111.