题名

平版印刷水槽液pH值測試量測不確定度評估個案研究

并列篇名

A Case Study of Estimating the Measurement Uncertainty of pH Measurement for Lithographic

DOI

10.30153/JCAGST.201003.0004

作者

張浩泓(Hao-Hung Chang);邱怡瑛(Ying-Yi Chiu);鄒勝峰(Sheng-Fong Tsou)

关键词
期刊名称

中華印刷科技年報

卷期/出版年月

2010(2010 / 03 / 01)

页次

73 - 80

内容语文

繁體中文

中文摘要

本文旨在介紹印刷水槽液pH值測試量測不確定度之估評。在文中,簡述水槽液pH值對平版印刷的影響,並且大篇幅地以實例敘述平版印刷水槽液之量測不確定度之過程,其內容包含量測不確定度誤差來源分析、估評方法、組合量測不確定度、擴充不確定度及擴充係數等。

英文摘要

The paper is aimed to introduce the estimation of the measurement uncertainty of pH measurement for lithographic fountain solution. In the paper, besides briefly describing about the effects of lithographic fountain solution, the authors apply an example to explain the process of estimating the measurement uncertainty of pH measurement for lithographic fountain solution. The process includes the analyses of sources of uncertainty, the methods of estimating, combined standard uncertainty, expanded uncertainty and coverage factor, etc.

主题分类 工程學 > 工程學總論
社會科學 > 傳播學
参考文献
  1. 財團法人印刷工業技術研究中心。印刷適性實驗室標準測試程序-酸鹼度標準測試程序。
  2. 設備校正報告。
  3. 設備使用說明書。
  4. 參考標準緩衝液Certificate of Analysis。
  5. NIEA W424.52A,水之氫離子濃度指數(PH值)測定方法-電極法。
  6. Nelson, R.E.,Terry, S.(1990).What the Printer Should Know about Ink.Pittsburgh, PA:Graphic Arts Technical Foundation.
  7. 古瓊忠(2003)。品質管制與檢驗─國際標準ISO17025實驗室品質與技術。台北:全華。
  8. 江瑞璋、林專仁(2009)。印刷因不標準所引發品質事故之探討。印刷科技,25(1)
  9. 徐章發行人(2006)。量測不確定度評估理論與實務。新竹:財團法人工業技術研究院測量發展中心。
  10. 徐照夫。量測技術導論。台中:財團法人塑膠工業技術發展中心。
  11. 財團法人全國認證基金會(2005)。TAFCNLA-G03測試結果量測不確定度評估指引。台北市:財團法人全國認證基金會。
  12. 財團法人印刷工業技術研究中心。印刷適性實驗室量測不確定度評估報告-酸鹼度量測不確定度評估報告印刷適性實驗室量測不確定度評估報告-酸鹼度量測不確定度評估報告,財團法人印刷工業技術研究中心。
  13. 賴文苓編。打造優質實驗室 part II參考例。台北:財團法人醫藥工業技術發展中心。
  14. 羅福林、李興才(1997)。印刷工業概論。台北:中國文化學華岡出版社。